FREE SHIPPING ON ORDERS OVER $200
{"id":769192493119,"title":"Grundfos GT-C Composite Tanks","handle":"grundfos-gt-c-composite-tanks","description":"\u003ch1\u003eGrundfos GT-C Composite Tanks\u003c\/h1\u003e\n\u003cp\u003eSpec Sheet: \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0007\/1702\/9439\/files\/Grundfosliterature-3980905.pdf?5341186010096632536\" target=\"_blank\" title=\"Grundfos GT-C Composite Tanks\" rel=\"noopener noreferrer\"\u003eGrundfos GT-C Composite Tanks\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePressure tanks - 60\/80\/130\/250 Litre capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eComposite tank Check air pressure prior to exposing to system pressure. - For pumps operating via a pressure switch set the air pressure at 90% of the minimum start pressure - For pumps operating at a constant pressure via a variable speed drive set the air pressure at 70% of the discharge operating pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cb\u003eGT-C-60 PN8.6 G1 V\u003c\/b\u003e\u003cbr\u003e\n\u003cp\u003eGrundfos GT-C-60 PN8.6 G1 V is a Diaphragm pressure tank, with a capacity of 60.0 l and Vertical installation. The tanks are approved for drinking water. The GT-C-60 PN8.6 G1 V is designed for a maximum operation pressure of 8.6 bar and a maximum liquid temperature of 50 °C.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a replaceable, non-toxic butyl rubber bladder enclosed by compressed nitrogen.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a replaceable, non-toxic butyl rubber bladder enclosed by compressed nitrogen. The tanks is mounted with a Manometer, that shows the system pressure. The tank has a pressure switch connection, that allows for connecting a pressure switch.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a non-toxic butyl rubber diaphragm with a precision-moulded polypropylene liner for superior air and water separation.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with double diaphragm. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with double diaphragm. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation. The tank has a FlowThru connection, which constantly flushes the tank while the pump is running. This ensures that the water in the tank remains fresh and eliminates the risk of stagnant water during normal system operation.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a lightweight composite pressure tank. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a lightweight composite pressure tank. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation. The tank has a FlowThru connection, which constantly flushes the tank while the pump is running. This ensures that the water in the tank remains fresh and eliminates the risk of stagnant water during normal system operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cp class=\"split\"\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a non-replaceable rubber diaphragm for heating applications. The tanks have a non-replaceable diaphragm that is pre-charged with nitrogen (1.5 bar). The tanks have a non-toxic butyl rubber diaphragm, dividing the tank chamber into two compartments. The upper compartment contains compressed nitrogen. The lower compartment has a liner of polypropylene (PP) and is filled with water from the pump.\u003c\/p\u003e\n\u003cp\u003eA pressure tank ensures controlled pressure in the water supply and thereby limits the switching frequency of the pump in case of low water consumption or leakage loss. The result is increased comfort in your installation by limiting the start\/stop frequency of your pump, and it increases system comfort by compensating for pressure drops when a tap is opened, while reducing problems with water hammer in the pipework.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0b5394;\"\u003eModels:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable width=\"323\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"134\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"189\"\u003e\u003cstrong\u003eModel Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"134\"\u003e'96733303\u003c\/td\u003e\n\u003ctd width=\"189\"\u003eGT-C-60 PN8.6 G1 V (60L 860kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e'96733304\u003c\/td\u003e\n\u003ctd\u003eGT-C-80 PN8.6 G1 V (80L 860kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e'96733306\u003c\/td\u003e\n\u003ctd\u003eGT-C-130 PN8.6 G1 V (130L 860kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e'96733308\u003c\/td\u003e\n\u003ctd\u003eGT-C-250 PN8.6 G1 1\/4 V (250L 860kPa)v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2018-06-25T13:30:25+08:00","created_at":"2018-06-25T13:42:44+08:00","vendor":"Grundfos","type":"Pressure Tanks","tags":["Grundfos","GrundfosBasicLine","Home Garden and Farm","Pressure Tanks"],"price":35265,"price_min":35265,"price_max":96631,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":8959544557631,"title":"GT-C-60 PN8.6 G1 V (60L 860kPa)","option1":"GT-C-60 PN8.6 G1 V (60L 860kPa)","option2":null,"option3":null,"sku":"96733303","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Grundfos GT-C Composite Tanks - GT-C-60 PN8.6 G1 V (60L 860kPa)","public_title":"GT-C-60 PN8.6 G1 V (60L 860kPa)","options":["GT-C-60 PN8.6 G1 V (60L 860kPa)"],"price":35265,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":""},{"id":8959544590399,"title":"GT-C-80 PN8.6 G1 V (80L 860kPa)","option1":"GT-C-80 PN8.6 G1 V (80L 860kPa)","option2":null,"option3":null,"sku":"96733304","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Grundfos GT-C Composite Tanks - GT-C-80 PN8.6 G1 V (80L 860kPa)","public_title":"GT-C-80 PN8.6 G1 V (80L 860kPa)","options":["GT-C-80 PN8.6 G1 V (80L 860kPa)"],"price":45360,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":""},{"id":8959544623167,"title":"GT-C-130 PN8.6 G1 V (130L 860kPa)","option1":"GT-C-130 PN8.6 G1 V (130L 860kPa)","option2":null,"option3":null,"sku":"96733306","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Grundfos GT-C Composite Tanks - GT-C-130 PN8.6 G1 V (130L 860kPa)","public_title":"GT-C-130 PN8.6 G1 V (130L 860kPa)","options":["GT-C-130 PN8.6 G1 V (130L 860kPa)"],"price":64552,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":""},{"id":8959544655935,"title":"GT-C-250 PN8.6 G1 1\/4 V (250L 860kPa)","option1":"GT-C-250 PN8.6 G1 1\/4 V (250L 860kPa)","option2":null,"option3":null,"sku":"96733308","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Grundfos GT-C Composite Tanks - GT-C-250 PN8.6 G1 1\/4 V (250L 860kPa)","public_title":"GT-C-250 PN8.6 G1 1\/4 V (250L 860kPa)","options":["GT-C-250 PN8.6 G1 1\/4 V (250L 860kPa)"],"price":96631,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0007\/1702\/9439\/products\/Grundfos-GT-C-Composite-Tanks.jpg?v=1561354275","\/\/cdn.shopify.com\/s\/files\/1\/0007\/1702\/9439\/products\/grundfos-gt-c-composite-tanks-pressure-tanks-grundfos-land-water-technology.jpg?v=1561354275","\/\/cdn.shopify.com\/s\/files\/1\/0007\/1702\/9439\/products\/grundfos-gt-c-composite-tanks-pressure-tanks-grundfos-land-water-technology-2.jpg?v=1561354275"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0007\/1702\/9439\/products\/Grundfos-GT-C-Composite-Tanks.jpg?v=1561354275","options":["Product Name"],"content":"\u003ch1\u003eGrundfos GT-C Composite Tanks\u003c\/h1\u003e\n\u003cp\u003eSpec Sheet: \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0007\/1702\/9439\/files\/Grundfosliterature-3980905.pdf?5341186010096632536\" target=\"_blank\" title=\"Grundfos GT-C Composite Tanks\" rel=\"noopener noreferrer\"\u003eGrundfos GT-C Composite Tanks\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePressure tanks - 60\/80\/130\/250 Litre capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eComposite tank Check air pressure prior to exposing to system pressure. - For pumps operating via a pressure switch set the air pressure at 90% of the minimum start pressure - For pumps operating at a constant pressure via a variable speed drive set the air pressure at 70% of the discharge operating pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cb\u003eGT-C-60 PN8.6 G1 V\u003c\/b\u003e\u003cbr\u003e\n\u003cp\u003eGrundfos GT-C-60 PN8.6 G1 V is a Diaphragm pressure tank, with a capacity of 60.0 l and Vertical installation. The tanks are approved for drinking water. The GT-C-60 PN8.6 G1 V is designed for a maximum operation pressure of 8.6 bar and a maximum liquid temperature of 50 °C.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a replaceable, non-toxic butyl rubber bladder enclosed by compressed nitrogen.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a replaceable, non-toxic butyl rubber bladder enclosed by compressed nitrogen. The tanks is mounted with a Manometer, that shows the system pressure. The tank has a pressure switch connection, that allows for connecting a pressure switch.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a non-toxic butyl rubber diaphragm with a precision-moulded polypropylene liner for superior air and water separation.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with double diaphragm. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with double diaphragm. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation. The tank has a FlowThru connection, which constantly flushes the tank while the pump is running. This ensures that the water in the tank remains fresh and eliminates the risk of stagnant water during normal system operation.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a lightweight composite pressure tank. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation.\u003c\/p\u003e\n\u003cp\u003eGT-C-60 PN8.6 G1 VThe tank is a lightweight composite pressure tank. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation. The tank has a FlowThru connection, which constantly flushes the tank while the pump is running. This ensures that the water in the tank remains fresh and eliminates the risk of stagnant water during normal system operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cp class=\"split\"\u003eGT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a non-replaceable rubber diaphragm for heating applications. The tanks have a non-replaceable diaphragm that is pre-charged with nitrogen (1.5 bar). The tanks have a non-toxic butyl rubber diaphragm, dividing the tank chamber into two compartments. The upper compartment contains compressed nitrogen. The lower compartment has a liner of polypropylene (PP) and is filled with water from the pump.\u003c\/p\u003e\n\u003cp\u003eA pressure tank ensures controlled pressure in the water supply and thereby limits the switching frequency of the pump in case of low water consumption or leakage loss. The result is increased comfort in your installation by limiting the start\/stop frequency of your pump, and it increases system comfort by compensating for pressure drops when a tap is opened, while reducing problems with water hammer in the pipework.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan style=\"color: #0b5394;\"\u003eModels:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable width=\"323\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"134\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"189\"\u003e\u003cstrong\u003eModel Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"134\"\u003e'96733303\u003c\/td\u003e\n\u003ctd width=\"189\"\u003eGT-C-60 PN8.6 G1 V (60L 860kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e'96733304\u003c\/td\u003e\n\u003ctd\u003eGT-C-80 PN8.6 G1 V (80L 860kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e'96733306\u003c\/td\u003e\n\u003ctd\u003eGT-C-130 PN8.6 G1 V (130L 860kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e'96733308\u003c\/td\u003e\n\u003ctd\u003eGT-C-250 PN8.6 G1 1\/4 V (250L 860kPa)v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

Grundfos GT-C Composite Tanks

Product Description
Product Name
Maximum quantity available reached.

Grundfos GT-C Composite Tanks

Spec Sheet: Grundfos GT-C Composite Tanks

Pressure tanks - 60/80/130/250 Litre capacity

Composite tank Check air pressure prior to exposing to system pressure. - For pumps operating via a pressure switch set the air pressure at 90% of the minimum start pressure - For pumps operating at a constant pressure via a variable speed drive set the air pressure at 70% of the discharge operating pressure.

GT-C-60 PN8.6 G1 V

Grundfos GT-C-60 PN8.6 G1 V is a Diaphragm pressure tank, with a capacity of 60.0 l and Vertical installation. The tanks are approved for drinking water. The GT-C-60 PN8.6 G1 V is designed for a maximum operation pressure of 8.6 bar and a maximum liquid temperature of 50 °C.

GT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a replaceable, non-toxic butyl rubber bladder enclosed by compressed nitrogen.

GT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a replaceable, non-toxic butyl rubber bladder enclosed by compressed nitrogen. The tanks is mounted with a Manometer, that shows the system pressure. The tank has a pressure switch connection, that allows for connecting a pressure switch.

GT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a non-toxic butyl rubber diaphragm with a precision-moulded polypropylene liner for superior air and water separation.

GT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with double diaphragm. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation.

GT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with double diaphragm. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation. The tank has a FlowThru connection, which constantly flushes the tank while the pump is running. This ensures that the water in the tank remains fresh and eliminates the risk of stagnant water during normal system operation.

GT-C-60 PN8.6 G1 VThe tank is a lightweight composite pressure tank. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation.

GT-C-60 PN8.6 G1 VThe tank is a lightweight composite pressure tank. The diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water separation. The tank has a FlowThru connection, which constantly flushes the tank while the pump is running. This ensures that the water in the tank remains fresh and eliminates the risk of stagnant water during normal system operation.

GT-C-60 PN8.6 G1 VThe tank is a steel pressure tank with a non-replaceable rubber diaphragm for heating applications. The tanks have a non-replaceable diaphragm that is pre-charged with nitrogen (1.5 bar). The tanks have a non-toxic butyl rubber diaphragm, dividing the tank chamber into two compartments. The upper compartment contains compressed nitrogen. The lower compartment has a liner of polypropylene (PP) and is filled with water from the pump.

A pressure tank ensures controlled pressure in the water supply and thereby limits the switching frequency of the pump in case of low water consumption or leakage loss. The result is increased comfort in your installation by limiting the start/stop frequency of your pump, and it increases system comfort by compensating for pressure drops when a tap is opened, while reducing problems with water hammer in the pipework.

Models:

Model Number Model Name
'96733303 GT-C-60 PN8.6 G1 V (60L 860kPa)
'96733304 GT-C-80 PN8.6 G1 V (80L 860kPa)
'96733306 GT-C-130 PN8.6 G1 V (130L 860kPa)
'96733308 GT-C-250 PN8.6 G1 1/4 V (250L 860kPa)v
Sku: 96733303