icon Skip to content
FREE SHIPPING ON ORDERS OVER $100 AUSTRALIA-WIDE* (T&C's Apply - exc Bulky Items)
FREE SHIPPING ON ORDERS OVER $100 AUSTRALIA-WIDE* (T&C's Apply - exc Bulky Items)

Bianco SPC LCD Single Pump Controller (2.2kW-15kW)

by Bianco
PN: 802687
Original price $517.44 - Original price $1,415.41
Original price
$1,109.26
$517.44 - $1,415.41
Current price $1,109.26

Bianco SPC LCD Single Pump Controller (2.2kW-15kW)

The iCON range of intelligent controllers are suitable for installation in various industrial and domestic applications. Controllers are generally used in pumping applications where control of single or multiple pumps are required. Settings for drainage, pressure boosting and transfer applications are easily accomplished by function switches. The iCON intelligent controller is user friendly with many features for controlling your pumps, protecting your pumps and also reporting of faults with live data and historical data retention. Control of your pumps is also possible from a slave controller which is included with each iCON intelligent controller as standard. The iCON controller is supplied standard with RS485 communication interface for easy integration into your Building Management System.

The iCON controller enclosure has an ingress protection rating IP54 with an intelligent dynamic LCD display for pump running information and is suitable for installation both indoors and outdoors. Automatic calibration of the iCON intelligent controller is easily completed to set your pump thermal overload by means of push buttons. Optional enclosure with an external door is available as required or requested.

Features

  • IP54 engineered plastic enclosure
  • Intelligent real-time LCD displays pump running information
  • Intelligent push button pump overload calibration prompts for uncompleted calibration
  • Function switch setting for drainage, pressure boosting, or transfer applications
  • Provision for up to 4 float switches/probes
  • Auto, manual switching
  • Visual and audible alarms
  • Adjustable time delay for audible alarm
  • Low voltage control circuit
  • RS485 communication interface (BMS, MODBUS)
  • Pump accumulated run time display
  • Last five pump faults logged into memory
  • Slave controller included
  • Control box contains MCB and DOL contactor
  • Provision for combinations of multiple device inputs and outputs for use with:
    • Float switches - Pumps with no float switch
    • High level float - Pumps with float switch
    • Level probes
    • Pressure switches
    • Hot water circulator system
    • Pressure transducer (DPC1-22S only)
    • External device alarms
  • Alternate pump starts, Automatic duty pump cycling, and load sharing

Protection

  • Pump stalled
  • Overload (restart attempt every 30 min. adj.)
  • Short circuit
  • Over voltage (restart attempt every 5 min. adj.)
  • Under voltage (restart attempt every 5 min. adj.)
  • Repeated starts (more than 5 per minute)
  • Open phase (3 phase only)
  • Phase reversal (3 phase only)
  • Three phase imbalance (3 phase only)
  • Over temperature (where pumps are fitted with micro-therms)
  • Anti-seize run timer (3sec every 240 hrs, adjustable)
  • Dry run protection without the need for a float switch or liquid level probe (restart attempt every 30 min. adj.
Model Voltage Power
BIA-SPC1-22 240V 2.2kW
BIA-SPC1-22S 240V 2.2kW
BIA-SPC3-40 415V 4kW
BIA-SPC3-110 415V 11kW
BIA-SPC3-150 415V 15kW